GB
English ................2
CZ
Česky .................8
DK
Dansk ................14
FI
Suomi ................20
HR
Hrvatski ..............27
HU
Magyar ...............33
NO
Norsk ................39
PL
Polski ................45
RU
Pуccкий ..............52
SE
Svenska ..............59
SI
Slovenščina ..........65
SK
Slovenčina ...........72
1
32
5
9
4
8
6
7
10
Printed in USA
2 3
English
Product description
1 Disposable Hygiene cap
(a box of 20 is supplied + 1 already installed)
2 Probe tip
3 Probe
4 ExacTemp® light
5 Hygiene cap ejector
6 Display
7 Power button
8 Start button
9 Battery door (2 X 1.5V type AA (LR6) batteries)
10 Protective cap
Intended use
The Braun ThermoScan® Ear thermometer is indicated for intermittent measurement and monitoring of human body
temperature for people of all ages. It is intended for household use only.
Use of IRT6515 along with fever guidance feature is not intended as a substitute for consultation with your physician.
Warnings and Precautions
Please consult your physician if you see symptoms such as unexplained irritability, vomiting,
diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, sti neck,
pain when urinating, etc. in spite of any colour of the background light or absence of fever.
Please consult your physician if the thermometer shows elevated temperature (yellow or red
background lights).
The operating ambient temperature range for this thermometer is 10 40 °C (50 104 °F). Do not expose the
thermometer to temperature extremes (below -25 °C / -13 °F or over 55 °C / 131 °F) or excessive humidity (>95% RH).
This thermometer must only be used with genuine Braun ThermoScan disposable Hygiene caps (LF 40).
To avoid inaccurate measurements always use this thermometer with a new, clean Hygiene cap attached.
If the thermometer is accidentally used without a Hygiene cap attached, clean the lens (see «Care and cleaning»
section). Keep Hygiene caps out of reach of children.
This thermometer is intended for household use only. This product is not intended to diagnose any disease, but is a
useful screening tool for temperature. Use of this thermometer is not intended as a substitute for consultation with
your physician.
The color-coded fever guidance feature is not intended for pre-term babies or small-for-gestational age babies.
Thecolor-coded fever guidance feature is not intended to interpret hypothermic temperatures. Do not allow children
under 12 to take their temperatures unattended.
Do not modify this equipment without authorization of the manufacturer.
Parents/guardians should call the pediatrician upon noticing any unusual sign(s) or symptom(s). For example, a child
who exhibits irritability, vomiting, diarrhea, dehydration, seizure, changes in appetite or activity, even in the absence of
fever, or who exhibits a low temperature, may still need to receive medical attention.
Children who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to
determine the severity of their illness.
Temperature elevation as indicated by the fever guidance feature may signal a serious illness, especially in adults who
are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately
when there is a temperature elevation and if you are taking temperature on:
neonates and infants under 3 months (consult your physician immediately if the temperature exceeds 37.4 °C
or99.4 °F)
patients over 60 years of age
patients having diabetes mellitus or a weakened immune system (e.g. HIV positive, cancer chemotherapy, chronic
steroid treatment, splenectomy)
patients who are bedridden (e.g. nursing home patient, stroke, chronic illness, recovering from surgery)
a transplant patient (e.g. liver, heart, lung, kidney)
Fever may be blunted or even absent in elderly patients.
This thermometer contains small parts that can be swallowed or produce a choking hazard to children. Always keep the
thermometer out of childrens reach.
Fever guidance feature
Fever guidance helps you to better understand the meaning of your child’s temperature with the color indicated on the
display. The screen displays green if no fever, yellow for fever and a red alert for a possibly high fever.
Color range Reading Meaning
Green > 35.7° – 37.4 °C
(> 96.3° – 99.4 °F) Normal
Yellow > 37.4° – 38.5 °C
(> 99.4° – 101.3 °F) Fever
Red > 38.5° – 42.2 °C
(> 101.3° – 108.0 °F) High fever
NOTE: Backlight remains OFF when below temperature readings are registered:
34.4° ≤ T ≤ 35.7 °C (93.9° ≤ T ≤ 96.3 °F)
How to use your Braun ThermoScan®
1. Remove protective cap.
2. Push the Power button .
During an internal self-check, the display shows all segments. Then the last temperature taken will be displayed for
5seconds.
3. The Hygiene cap indicator will blink to signal one is needed.
To achieve accurate measurements, make sure a new, clean Hygiene cap
is in place before each measurement.
Attach a new Hygiene cap by pushing the thermometer probe straight
into the Hygiene cap inside the box and then pulling out.
Note: The Braun ThermoScan will not work unless a Hygiene cap is
attached.
4. The thermometer is ready to take a temperature when the display looks like the image below.
4 5
English
5. Fit the probe snuggly into the ear canal and direct towards opposite
temple. Then push and release the Start button .
6. ExacTemp® light will pulse while temperature measurement is in progress. The light will remain
solid for 3 seconds to indicate that a successful temperature reading has been achieved.
NOTE: If the probe has been properly inserted into the ear canal during the measurement, a
long beep will sound to signal the completed measurement.
If the probe has not been constantly placed in a stable position in the ear canal, a sequence of
short beeps will sound, the ExacTemp light will go out and the display will show an error
message (POS = position error).
See «Errors and troubleshooting» section for more information.
7. The conrmation beep indicates that an accurate temperature measurement has
been taken. The result is shown on the display. Temperature reading displayed is
an equivalent of oral temperature.
To repeat
Go to step 3.
8. For the next measurement, press Eject button to remove and discard
used Hygiene cap, and put on a new, clean Hygiene cap.
NOTE: Defaults to last age setting used if you do not change.
The Braun ThermoScan Ear thermometer turns o automatically after
60seconds of inactivity. The thermometer can also be turned o by
pressing the Power button .
The display will briey ash OFF and it will go blank.
Temperature-taking hints
Replace disposable Hygiene cap with every use to maintain accuracy,
hygiene and to prevent cross-contamination. Earwax and dirt on the tip of
the Hygiene cap, even in a microscopic layer, can create an obstacle
between the sensor and the infrared heat emitted by the ear and impact the
accuracy of the measurement.
External factors like poor probe replacement, used Hygiene cap or dirty Hygiene
cap may inuence ear temperature measurements.
In clinical studies, precision and accuracy of ear thermometer measurement has been shown to be inuenced by
variability in user technique. Correct probe placement is essential for accurate measurements.
High fever
Fever
Normal
Red
Yellow
Green
Temperature in right and left ear diers, always compare measurements from the same ear. The natural
physiological dierence may reach 0.2 °C. In the absence of confounding factors, in high-risk population (like infants or
immunodepressed people) use the highest of the two to interpret the patient’s temperature.
In the following cases, wait 20 minutes prior to taking a temperature: extreme changes in room temperature, hearing
aid, lying on a pillow. Use the untreated ear if ear drops or other medications have been placed in the ear canal.
Memory mode
1. The last temperature taken is stored in its memory and will be
automatically displayed for 5 seconds when it is turned on again.
Night light feature
The thermometer includes a convenient night light to illuminate the display in a dim
environment.
The light will turn on when you press any button. It will stay on until the thermometer is inactive
for up to 15 seconds even after temperature is taken.
Changing the temperature scale
Your Braun ThermoScan is shipped with the Celsius (°C) temperature scale activated. If you wish to switch to Fahrenheit
(°F) and/or back from Fahrenheit to Celsius, proceed as follows:
1. Make sure the thermometer is turned o.
2. Press and hold down the Power button . After about 3 seconds the display will show this
sequence: °C / SET / °F / SET.
3. Release the Power button when the desired temperature scale is shown. There will be a
short beep to conrm the new setting, then the thermometer is turned o automatically.
Care and cleaning
The probe tip is the most delicate part of the thermometer. It must be clean and intact to ensure accurate
readings. If the thermometer is ever accidentally used without a Hygiene cap, clean the probe tip as follows:
Very gently wipe the surface with a cotton swab or soft cloth moistened with alcohol. After the
alcohol has completely dried out, you can put a new Hygiene cap on and take a temperature
measurement.
If the probe tip is damaged, please contact Consumer Relations.
Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners.
Never submerge this thermometer in water or any other liquid. Store thermometer and Hygiene
caps in a dry location free from dust and contamination and away from direct sunlight.
Additional Hygiene caps (LF 40) are available at most stores carrying Braun ThermoScan.
6 7
English
Replacing the batteries
The thermometer is supplied with two 1.5 V type AA (LR 06) batteries.
1. Insert new batteries when the battery symbol appears on the display.
2. Open the battery compartment. Remove the batteries and replace with new batteries, making
sure the poles are in the right direction.
3. Snap battery door into place.
Errors and troubleshooting
Error Message Situation Solution
No Hygiene cap is attached. Attach new, clean Hygiene cap.
The thermometer probe was not positioned
securely in the ear.
An accurate measurement was not possible.
POS = position error
Take care that the positioning of the probe is correct
and remains stable.
Replace Hygiene cap and reposition.
Press Start button to begin a new measurement.
Ambient temperature is not within the
allowed operating range
(10 – 40 °C or 50 – 104 °F).
Allow the thermometer to remain for 30 minutes
in a room where the temperature is between
10 and 40 °C
or 50 and 104 °F .
Temperature taken is not within typical
human temperature range
(34 – 42.2 °C or 93.2 – 108 °F).
HI = too high
LO = too low
Make sure the probe tip and lens are clean and a
new, clean Hygiene cap is attached. Make sure the
thermometer is properly inserted. Then, take a new
temperature.
System error – self-check display ashes
continuously and will not be followed by the
ready beep and the ready symbol.
If error persists,
If error still persists,
Wait 1 minute until the thermometer turns o
automatically, then turn on again.
... reset the thermometer by removing the batteries
and putting them back in.
... please contact the Service Centre.
Battery is low, but thermometer will still
operate correctly. Insert new batteries.
Battery is too low to take correct
temperature measurement. Insert new batteries.
ThermoScan
Product specications
Displayed temperature range: 34 – 42.2 °C (93.2 – 108 °F)
Operating ambient temperature range: 10 – 40 °C (50 – 104 °F)
Storage temperature range: -25 – 55 °C (-13 – 131 °F)
Operating and storage relative humidity: 10-95% RH (non condensing)
Display resolution: 0.1 °C or °F
Accuracy for displayed temperature range Maximum Laboratory Error
35 – 42 °C (95 – 107.6 °F): ±0.2 °C (±0.4 °F)
Outside this range: ±0.3 °C (±0.5 °F)
Clinical repeatability: ±0.14 °C (±0.26 °F)
Battery life: 2 years / 350 measurements
Service life: 5 years
This thermometer is specied to operate at 1 atmospheric pressure or at altitudes with an atmospheric pressure up to 1
atmospheric pressure (700 - 1060 hPa).
10 °C
40 °C
Equipment with type BF applied parts See Instruction for use Operating temperature Storage temperature Keep it dry
Subject to change without notice.
This product conforms to the provisions of the EC directive 93/42/EEC. This product carries the CE mark and is
manufactured in conformity with the RoHS Directive 2011/65/EU.
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For detailed description of EMC
requirements please contact your authorized local Service Centre (See guarantee card).
Portable and mobile RF communications equipment can aect MEDICAL ELECTRICAL EQUIPMENT.
This product contains batteries and recyclable electronic waste. To protect the environment, do not dispose of it
in the household waste, but take it to appropriate local collection points.
Calibration
This product has been calibrated at the time of manufacture. If used according to the use instructions, periodic
calibration is not required. This device is not intended as a substitute for regular check-ups by your doctor, please
consult your doctor if you have any doubt about the temperature reading. LOT and Serial numbers of your product
must be provided as they are essential to record and follow up your inquiry or claim.
Manufacturing date is given by the LOT number located in the battery compartment.
The rst three (3) digits after LOT represent the Julian date that the product was manufactured and the next two (2)
digits represent the last two numbers of the calendar year the product was manufactured. The last identiers are the
letters that represent the manufacturer.
An example: LOT 11614k, this product has been manufactured on the 116th day of the year 2014.
Guarantee
EMC Tables and Consumer Card are available on our website at www.hot-europe.com/support.
For support requests, please visit www.hot-europe.com/support or nd service contact information on the last page of
this manual.
UK only: This guarantee in no way aects your rights under statutory law.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 40 618 750 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756