Znaleziono w kategoriach:
Termometr BABYONO 790

Instrukcja obsługi Termometr BABYONO 790

Powrót
EN
PL
BG
CZ
HR
HU
LT
NL
MD, RO
RU
SK
UA
2
8
14
20
26
32
38
44
50
56
62
68
Non-contact infrared thermometer
Termometr bezdotykowy
Безконтактен инфрачервен термометър
Bezkontaktní infračervený teploměr
Beskontaktni infracrveni termometar
Érintés nélküli infravörös hőmérő
Nekontaktinis infraraudonųjų spindulių termometras
Contactloze infraroodthermometer
Termometru cu infraroșu fără contact
Термометр инфракрасный бесконтактный
Bezkontaktný infračervený teplomer
Термометр інфрачервоний безконтактний
Cat. No 790
2
Model: JXB-311
THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION
Instruction version: V.00 17.12.2021
I. Safety precautions
Follow the maintenance advice stipulated in this instruction manual.
This device may be used for professional purposes or for personal home use.
This device must be used for the purposes described in this instruction manual only.
This device must be used in an ambient temperature range of between 10°C and 40°C only.
This device must always be kept in a clean, dry area.
Do not expose this thermometer to electric shocks.
Do not expose this thermometer to extreme temperature conditions of 55°C or -20°C.
Do not use this device in relative humidity higher than 85%.
The protective glass over the lens is the most fragile part of the thermometer.
Do not touch the glass of the infrared lens with your ngers.
Clean the glass with a cotton bud lightly moistened with 95° alcohol.
Do not expose the thermometer to sunlight or to water.
Never drop the device.
Should a problem occur with your device, please contact your retailer.
Do not attempt to repair this device by yourself.
Disposal of waste products, residues, etc., and of me equipment and accessories at the end of their expected service life are identied in the instruction for use.
II. Intended use
The device is an infrared thermometer intended to measure forehead temperature of infants and adults without contacting human body. It can be used by consumers in
household environment and doctor in clinic as reference.
III. Introduction
The JXB-311 Non-contact Infrared thermometer has been developed by using the latest infrared technology. This technology allows temporal artery (TA) temperature to
be taken at a distance of about 0cm~3cm away from the forehead. Precise, Instantaneous and without Contact, the JXB-311 is, up to now, the most suitable thermometer
for no risk on temperature measurement. It has been demonstrated that this method of TA temperature measurement is more precise than the tympanic thermometry
and better tolerated than rectal thermometry (1). However, as with other types of thermometer, it is essential to use the JXB-311 properly in order to obtain reliable and
stable results. You are therefore advised to read this instruction manual and the safety precautions carefully before use. (1)Greenes D, Fleisher G. Accuracy of a Noninvasive
Temporal Artery Thermometer for Use in Infants. Arch Pediatr Adolesc Med 2001;155:376.
IV. Precautions before use
The JXB-311 is pre-set at the factory. It is not necessary to calibrate the device when starting it up. In order to obtain reliable and stable results, you are advised each time
there is a signicant change in the ambient temperature due to a change in environment, to allow the JXB-311 to acclimatize to this ambient temperature for 15 to 20
minutes before using it. It is important to allow 3~5 seconds interval between two measurements.
V. Operating principle
All objects, solid, liquid or gas, emit energy by radiation. The intensity of this energy depends on the temperature of the object.The JXB-311 infrared thermometer is
therefore able to measure the temperature of a person by the energy the person emits. This measurement can be taken thanks to anexternal temperature probe on the
device which permanently analyses and registers the ambient temperature. Therefore, as soon as the operator holds the thermometer near the body and activates the
radiation sensor, the measurement is taken instantly by detection of the infrared heat generated by the arterial blood ow. Body heat can therefore be measured without
any interference from the heat of the surrounding environment.
THE DIFFERENT METHODS OF TEMPERATURE MEASUREMENT
Core temperature
Core temperature is the most precise measurement and involves measuring the temperature in the pulmonary artery by means of a catheter equipped with a thermal
probe which can read the temperature in situation. The same method is employed for probes measuring the oesophageal temperature. However, such invasive
temperature measurement methods require specic equipment and expertise.
Rectal thermometry
Rectal temperature adjusts slowly in comparison to the evolution of the body’s internal temperature. It has been demonstrated that rectal temperature remains raised
long after the internal temperature of the patient has started to drop and vice versa. Furthermore, rectal perforations have been known to occur as a result of this method
and without appropriate sterilisation techniques, rectal thermometry can spread germs often found in faeces.
EN Non-contact infrared thermometer
3
Oral thermometry
Oral temperature is easily inuenced by recent ingestion of food or drinks and by breathing through the mouth. To measure oral temperature, the mouth must remain
closed and the tongue lowered for three to four minutes which is a dicult task for young children to accomplish.
Axillary (armpit) temperature
Although it may be easy to measure axillary temperature, it has been proven that it does not provide an accurate measurement of the child’s internal temperature. To take
this type of temperature, the thermometer must be wedged tightly over the axillary artery. Despite the low sensitivity and relative inaccuracy of axillary temperature in
detecting fever, this method is recommended by The American Academy of Pediatrics as a screening test for fever in newborns.
Tympanic thermometry
In order to obtain a precise temperature reading, good command of the measurement technique is required. The thermometer probe must be placed as close as possible
to the warmest part of the external ear canal.
Normal temperatures according to measurement method
MEASUREMENT METHOD NORMAL TEMP°
RECTAL 36.6°C ~ 38°C
ORAL 35.5°C ~ 37.5°C
AXILLARY 34.7°C ~ 37.3°C
AURICULAY 35.8°C ~ 38°C
TEMPORAL 35.8°C ~ 37.8°C
The temperature of the human body varies throughout the day. It can also be inuenced by numerous external factors: age, sex, type and thickness of skin…
Advantages of temporal artery (ta) temperature
Infrared arterial temperature can be measured using a device placed on the forehead, in the temporal artery region. It has been demonstrated that this relatively new
method of measuring temperature is more precise than tympanic thermometry and better tolerated than rectal thermometry. The JXB-311 thermometer has been
designed to produce an instant forehead temperature reading without any contact with the temporal artery. As this artery is quite close to thesurface of this skin and
therefore accessible and given the blood ow is permanent and regular, it allows precise measurement of the temperature. This artery is linked to the heart by the carotid
artery which is directly linked to the aorta. It forms part of the main trunk of the arterial system. The eciency, speed and comfort of taking a temperature from this area
make it ideal compared with other temperature measurements methods.
Normal temperature according to age
Age °C °F
0-2 years 36.4-38.0 97.5-100.4
3-10 years 36.1-37.8 97.0-100.0
11-65 years 35.9-37.6 96.6-99.7
> 65 years 35.8-37.5 96.4-99.5
Practical considerations when taking a temperature
In order to ensure that precise and accurate temperature measurements are obtained, it is essential that each user has received adequate information on and training
in the temperature measurement technique when using such a device.
It is essential to remember that although procedures such as taking a temperature may be simple they must not be trivialised.
Temperature should be taken in a neutral context. The patient must not have undertaken vigorous physical activity prior to taking his/her temperature and the room
temperature must be moderate.
Be aware of physiological variations in temperature which must be taken into consideration when evaluating the results: temperature increases by 0.5°C between 6
am and 3 pm. Women have a temperature that is higher, on average, by around 0.2°C. Their temperature also varies in accordance with their ovarian cycle. It rises by
0.5°C in the second half of the cycle and at the early stages of pregnancy.
When sitting, temperature is lower by about 0.3°C to 0.4°C than when standing.
How to take a temperature
Aim at the FOREHEAD, over the right temporal region, from a distance of about °Cm~3cm, press the thermometer’s measurement button and the temperature
is instantly displayed. The reliability of the measurement cannot be guaranteed if the temperature is measured over another part of the body (e.g.arm, torso…)
Constraints
Please observe the following before any temperature measurement to ensure a stable and reliable result:
Push back hair from the forehead.
Wipe away any perspiration from the forehead.
Avoid any drafts (e.g. from nasal specs, air conditioning…)
Allow a 3~5 seconds interval between two measurements.
Each time there is a signicant change in the ambient temperature due to a change in environment, to allow the JXB-311 to acclimatise to this ambient temperature
for at least 15 minutes before using it.
4
VI. Basic instrument
The type BF applied part: Sensor.
VII. Features
1. Special design to take the Human Body Temperature with a °Cm~3cm (0~1.2 in) distance from forehead.
2. Reliable and stable measurement, thanks to the advantage Infrared Detection System.
3.Vibration alarm if temperature is more than 38°C (100.4°F).
4.Memorize the last 32 temperature measurements.
5.White color LED digital display Screen.
6. Temperature unit can be displayed in either Celsius or Fahrenheit.
7.Automatic power-o ( < 30 secs) to conserve energy.
8.Longevity use (100,000 readings).
9.Practical, easy to use.
Additional usage:
JXB-311 can also be used to measure the temperature of a baby-bottle or bath (by using the Surface Temp Mode), or room temperature (by using the Room Mode).
VIII. Instructions
1.Install battery.
2.For the rst use or when inserting new Battery, wait from 10~15 minutes for the warm-up of the unit. This will allow the unit to become acclimated to the temperature
of the room.
3.When measuring the body temperature, the product should be pointed to the center of the forehead - - it should keep vertical and above the eyebrow. The
measurement area should not be covered by hair, the product and the forehead’s distance should be kept within 3cm (the optimal distance is the adult index nger’s
thickness). Do not touch the forehead directly. In the switch on state, press the button to take the temperature, and the product body will be vibrated, and the
measurement is completed, At the same time the screen will display the measure data.
Tip 1: The product cannot be removed from the location when the measurement is not completed. 4.Before taking the temperature, make sure to remove hair and
perspiration from the forehead.
IX. Setting and function of menu
1.Switch on the device
Press the button one second after the screen panel in full display, it will enter the standby mode with the sign “---°C” or “----°F”. Then press the button again,
you will get the measuring result in 1 second. But if there is no more operation, it will turn o in 30 seconds automatically, or press the button more than 3 seconds
will be turned o.
2.Temperature mode setting
In the switch on state, press the “MODE” button, the screen will display , it is “Body temperature mode”. When press the “MODE” button again, the screen will
display , it is “Surface temperature mode”. Press “MODE” button again, the screen will display , it is “Room temperature mode. Note: The thermometer default
is set to Body temperature mode.
3.Temperature overall oset setting
Under the standby mode, press and hold the “MODE” button for 2 seconds. After the screen displays “F4”, enter the temperature overall oset setting. When and
“0.0°C” is ashing, press the “MEM” button to increase .1°C, press button to decrease 0.1°C, oset value can be in range of -3°C ~ 3°C by the internal setting, press
the “MODE” button twice, and the setting data will be returned to the standby state. Note: The thermometer default is set to +0.0°C.
4.Temperature unit setting In the switch on state, press and hold the “MODE” button for 2 seconds, the screen will display “F4”, press the “MODE” button again, the screen
will display “F5”, when enter the temperature unit setting, then “F5” and the unit symbol “°C” or “°F” will be ashed continuously, press the “MEM” button to select Celsius
°C, press the button to select Fahrenheit °F, then press the “MODE” button to save and return to the standby state.
5.Memory query and clear
In the switch on state, press the “MEM” button, the screen will display the
last measured data, and can review up to 32 groups of the data. press the
“MEM” button for 5 seconds, all current memory data will be cleared, and
restore to the factory setting.
LED panel
Mem Button
On/Scan Button
Infrared sensor
Mode Button
Battery compartment
Non-contact Infrared
Thermometer
Model No.: JXB-311
Measuring distance: ≤3cm
Batteries: DC 3V
Made in China
Body temperature mode
Surface temperature mode
Room temperature mode
Celsius
Temperature
Fahrenheit
Memory
Low Battery
5
6.Over temperature prompt function
Under the body temperature mode, if the measured body temperature is
higher than or equal to 38.0°C, the product will be vibrated for three times.
7.Changing the batteries
Display: when the LED screen displays the ashed symbol , the battery needs to change. Operation: Open the lid and change the batteries, taking great care with
the correct positioning. A mistake with this could cause damage to the apparatus and compromise the guarantee of your JXB-311. Never use rechargeable batteries.
Use only batteries for single usage.
X. Technical specications
1.Normal using condition
Ambient temperature: 10°C ~ 40°C (50°F ~ 104°F)
Relative humidity: ≤ 85%
Pressure altitude: 700 hPa to 1060 hPa
2.Storage and shipping condition
Ambient temperature: -20°C ~ 55°C (-4°F ~ 131°F)
Relative humidity: ≤ 95%
3.Batteries: DC 3V (2 pcs AAA batteries)
4.Unit size: 154 x 40 x 31 mm (L x W x H)
5.Unit weight (without battery): 64g
6.Temperature display resolution: 0.1°F (0.1°C)
7.Measuring range:
In body mode: 32°C ~ 43°C (89.6°F ~ 109.4°F)
In surface temp mode: 0°C ~ 60°C (32°F ~ 140°F)
In room mode: 0°C ~ 40°C (32°F ~ 104°F)
8.Precision:
32.0°C ~ 34.9°C (89.6°F ~ 94.8°F) ±0.3°C(±0.6°F)
35.0°C ~ 42.0°C (95.0°F ~ 107.6°F) ±0.2°C(±0.4°F)
42.1°C ~ 43.0°C (107.8°F ~ 109.4°F) ±0.3°C(±0.6°F)
9.Consumption: ≤300mW
10.Accuracy: ±0.6°F (0.3°C)
11.Measuring distance: ≤3cm (1.2in)
12.Automatic power-o: <30 secs
13.Memory: 32 sets
14. Measuring position: Forehead skin
Note: The Non-contact Infrared Thermometer Model JXB-311 can take temperature readings below 32°C or above 43.0°C (89.6°F to 109.4°F) but precision is not guaranteed
outside of this range. Longevity of the product. The JXB-311 was conceived for an intense and professional use, its longevity is guaranteed for 100,000 takings.
XI. Maintenance of the product
- The protective glass over the lens is the most important and fragile part of the thermometer, please take great care of it.
- Clean the glass with cotton fabric, wet with 95° alcohol.
- Do not use other batteries than mentioned batteries, do not recharge non rechargeable batteries, do not throw in re.
- Remove the batteries when thermometer is not used for an extended period of time.
- Do not expose the thermometer to sunlight or water.
- An impact will damage the product.
XII. Accessories
User Manual in English 1 pc
AAA alkaline batteries 2 pcs
XIII. Guidelines
This device complies with the EU Directive 93/42/EEC concerning medical products the ISO 80601-2-56 and the European Standard EN60601-1-2 and is subject to
particular precautions with regard to electromagnetic compatibility.
XIV. Troubleshooting
If you have problems while using your thermometer, please refer to this guide to help resolve the problem. If the problem persists, please contact our customer service.
THE SCREEN DISPLAYS TEMPERATURE HIGHER THAN 43.0°C (109.4°F):
The temperature is in Fahrenheit. Change the measurement to Celsius.
THE SCREEN DISPLAYS TEMPERATURE LOWER THAN 32°C (89.6°F):
To take the surface temperature, press the “BODY” button and set to the reading called “Body” , If the device is in Surface Temp Mode, the 32°C
(89.6°F) temperature displayed is showing the external temperature of your body, rather than the internal.
THE SCREEN DISPLAYS THE MESSAGE HI
When using the JXB-311 Thermometer, the message “HI” can show on the screen. In this case,the temperature is above the measurement range selected, either above
43.0 °C (109.4°F) in Body Mode.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 40 618 750 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756