Znaleziono w kategoriach:
Klimatyzator Split, Pompa ciepła powietrze - powietrze WHIRLPOOL SPIW309A3WF.1

Instrukcja obsługi Klimatyzator Split, Pompa ciepła powietrze - powietrze WHIRLPOOL SPIW309A3WF.1

Powrót
Instructions for use
Gebrauchsanweisung
Directives d’utilisation
Gebruiksaanwijzing
Instrucciones de uso
Instrucciones de uso
Libretto di istruzioni
Οδηγίες χρήσης
Bruksanvisning
Bruksanvisning
Brugsanvisninger
Käyttöohjeet
Instrukcja użytkownika
Návod k obsluze
Návod na používanie
Használati útmutató
Инструкция по эксплуатации
Инструкции за използване
Instrucţiuni de utilizare
Інструкції з використання
- 3 -
ENGLISH Instructions for use Page 4
DEUTSCH Bedienungsanleitung Seite 20
FRANÇAIS Consignes d’utilisation Page 36
NEDERLANDS Gebruiksaanwijzing Pagina 52
ESPAÑOL Instrucciones de uso Página 68
PORTUGUÊS Instruções de utilização Página 84
ITALIANO Istruzioni per l’uso Pagina 100
ΕΛΛΗΝΙΚΑ Οδηγίες χρήσης Σελίδα 116
SVENSKA Bruksanvisning Sidan 132
NORSK Brukerveiledning Side 148
DANSK Brugsanvisninger Side 164
SUOMI Käyttöohje Sivu180
POLSKI Instrukcja użytkownika Strona 196
ČESKY Návod kobsluze Strana 212
SLOVENSKÝ Návod na používanie Strana 228
MAGYAR Használati útmutató 244. oldal
РУССКИЙ Инструкция по эксплуатации Стр. 260
БЪЛГАРСКИ Инструкции за използване Страница 276
ROMÂNĂ Instrucţiuni de utilizare Pagina 292
УКРАЇНСЬКА Інструкції з використання стор.308
SPIW309A3WF.1
SPIW312A3WF.1
SPIW309A2WF
SPIW312A2WF
SPIW318A2WF
SPIW309L
SPIW312L
SPIW318L
- 4 -
IMPORTANT TO BE READ AND OBSERVED
Download the complete instruction manual on docs.whirlpool.eu or call the phone
number shown on the warranty booklet.
Before using the appliance, read these safety instructions. Keep them nearby for future
reference.
These instructions and the appliance itself provide important safety warnings, to be
observed at all times. The manufacturer declines any liability for failure to observe these
safety instructions, for inappropriate use of the appliance or incorrect setting of controls.
Very young children (0-3 years) should be kept away from the appliance. Young
children (3-8 years) should be kept away from the appliance unless continuously
supervised. Children from 8 years old and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge can use this
appliance only if they are supervised or have been given instructions on safe use and
understand the hazards involved. Children must not play with the appliance. Cleaning
and user maintenance must not be carried out by children without supervision.
PERMITTED USE
CAUTION: the appliance is not intended to be operated by means of an external
switching device, such as a timer, or separate remote controlled system.
This appliance is intended to be used in household and similar applications such as:
hotels and working oces.
This appliance is not for professional use.
Always turn o the air conditioner by remote control rst. Do not use the power supply
circuit breaker or pull o the plug to turn it o. Disconnect the air conditioner from the
power supply if it is to be left unused for a long period of time or during a thunder/
lightning storm.
Never insert obstacle in the air outlet-risk of injury. Keep ventilation openings clear of any
obstruction.
Do not place any other electrical products or household belongings under indoor unit
or outdoor unit. Condensation dripping from the unit might get them wet, and may cause
damage or malfunction of your property.
INSTALLATION
The appliance must be handled and installed by two or more persons - risk of injury.
Use protective gloves to unpack and install - risk of cuts.
Installation, including electrical connections, and repairs must be carried out by a
qualied technician according to national wiring rules. Do not repair or replace any
part of the appliance unless specically stated in the user manual. Keep children away
from the installation site. After unpacking the appliance, make sure that it has not
been damaged during transport. In the event of problems, contact the dealer or your
nearest After-sales Service. Once installed, packaging waste (plastic, styrofoam parts
etc.) must be stored out of reach of children - risk of suocation. The appliance must be
disconnected from all remote power supply before any installation operation - risk of
electric shock. During installation, make sure the appliance does not damage the power
cable - risk of re or electric shock. Only activate the appliance when the installation has
been completed.
SAFETY INSTRUCTIONS
- 5 -
When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the unit.
The appliance shall not be installed in the laundry.
ELECTRICAL WARNINGS
The power supply must be of rated voltage with special circuitry for the appliance.
The diameter of the power cord must comply with requirements.
A multi-pole switch shall be installed in the xed wiring in accordance with the wiring
rules and the appliance must be earthed in conformity with national electrical safety
standards.
An all-pole disconnection switch having a contact separation of at least 3 mm in all poles
should be connected in xed wiring.
Do not use extension leads, multiple sockets or adapters. The electrical components
must not be accessible to the user after installation. Do not use the appliance when you are
wet or barefoot. Do not operate this appliance if it has a damaged power cable or plug, if it
is not working properly, or if it has been damaged or dropped.
If the supply cord is damaged, it must be replaced with an identical one by the
manufacturer, its service agent or similarly qualied persons in order to avoid a hazard - risk
of electrical shock.
A residual current device (RCD) having rated residual operation current not exceeding
30 mA shall be incorporated in xed wiring according to national law.
The temperature of refrigerant circuit will be high, please keep the interconnection cable
away from the copper tube.
Ensure safe grounding and a grounding wire connected with the special grounding
system of the building, installed by professionals. The appliance must be tted with
electrical leakage protection switch and an auxiliary circuit breaker with sucient capacity.
The circuit breaker must also have a magnetic and a thermal tripping function to ensure
protection in case of short-circuit and overload.
Model 9K & 12K 18K 24K
Required capacity of circuit breaker 16A 20A 25A
For the connection of power cord and cable connection between indoor and outdoor
units, please see the wiring diagram on the appliance.
CLEANING AND MAINTENANCE
WARNING: Ensure that the appliance is switched o and disconnected from the
power supply before performing any maintenance operation; never use steam cleaning
equipment - risk of electric shock.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of ammable
refrigerants.
Servicing shall only be performed with equipment as recommended by the
manufacturer.
DISPOSAL OF PACKAGING MATERIALS
The packaging material is 100% recyclable and is marked with the recycle symbol ( ). The various parts of the
packaging must therefore be disposed of responsibly and in full compliance with local authority regulations
governing waste disposal.
SAFETY INSTRUCTIONS

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 40 618 750 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756