IMPORTANT INSTRUCTIONS OF THE DEVICE
• Blood pressure should be judged by a medical doctor or other medical specialist who is familiar with your case
history. Through the regular use of the blood pressure gauge you can continuously record your pressure values.
These records can be used for therapeutic purposes.
• Tightly wrap the cu around your upper arm. The cu must be positioned on the level of the heart.
• The monitor must not be moved or shaken during measuring as this would lead to inaccurate results.
• Carry out measuring in a still and relaxed position.
• Do not wrap the cu around the sleeve of a jacket, shirt which could make measuring impossible.
• Keep in mind that blood pressure naturally varies in the course of the day and is inuenced by many dierent
factors as, e.g., smoking, alcohol, drugs and physical eort. We recommend not to smoke, eat or do physical exercises
for about 30 minutes before measuring.
• To the people with following condition which leads to circulatory disorders (diabetes, kidney diseases, hardening of
the arteries), the values measured with this device may be lower than those measured with a gauge taking the blood
pressure at the upper arm. Consult your doctor to make sure that measuring blood pressure at your upper arm leads
to accurate measuring values.
• The measuring device is designed for the measuring of blood pressure in adults only.
• Do not use the device if your upper arm is injured.
• If the automatic ination function of the cu does not stop automatically it must be opened and taken o imme-
diately!
Note: This device is not suitable for invasive blood pressure measuring in adults or children. It may only be used for
non-invasive blood pressure monitoring and only in adults!
PARTS DESCRIPTION
A. Cu jack
B. Type-C jack
C. LCD display
D. SET button
E. MEM button
F. START/STOP button
THE SYMBOLS ON THE LCD DISPLAY
1. Systolic blood pressure
2. Diastolic blood pressure
3. WHO classication symbol ( blood
pressure level )
4. Pulse display
5. Low battery symbol
6. Date/Time display
7. Average value symbol (AVG)
6. Memory symbol (M)
9. User 1
10. User 2
11. Irregular heartbeat symbol
12. Heartbeat symbol (ashes during
measurement)
13. Number of measurement memorry
14. Light indicator of WHO classication
Light indicator color / Blood pressure level related to blood pressure value
Light indicator of WHO classi-
cation
WHO classication symbol (
blood pressure level )
Blood pressure value
Green 1SYS<120 & DIA<80
Green 2120≤SYS<130 80≤DIA<85
Yellow 3 130≤SYS<140 85≤DIA<90
Yellow 4140≤SYS<160 90≤DIA<100
1
14
3
2
4
3
9
10
7
13
11
12
5
8
A
D
E
F
C
B
Red 5160≤SYS<180 100≤DIA<110
Red 6SYS>180 DIA>110
USING THIS DEVICE FOR THE FIRST TIME
Selecting the power source
You can optionally operate the device by a AC adapter with type C connector (output : DC, 5V, 1A) or 1.5V AA
alkaline batteries. Note : AC adpater is not included in the set,
Using the AC adpater
• Use only the CE approved AC adapter to avoid damaging the device.
• Ensure that the AC adapter and cable are not damaged.
• Plug the adapter cable into the AC adapter jack on the right side of the device.
• Plug the adapter into your mains outlet. When the AC adapter is connected, no battery current is consumed.
Battery Installation
• Lift the hook on the bottom of the battery cover and lift the cover o in the direction of the arrow.
• Install 3 AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compart-
ment, replace the battery cover.Make sure that the battery cover is securely in position.
Battery replacement
Low Battery Indicator
• When the Low Battery Indicator appears on the display, turn the device o and remove all the batteries. Replace
with 3 new batteries at the same time. Long-life alkaline batteries are recommended.
• To prevent the damage of device from leaked battery uid, please take out of battery if the device unused in a long
time(generally more than 3 months). If battery uid should get in your eyes, immediately rinse with plenty of clean
water. Contact a physician immediately.
• Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful
disposal may cause environmental pollution.
SYSTEM SETTINGS
Before setting, ensure that all batteries are loaded correctly or AC adapter connected correctly.
Time setting
Long press the SET button for 3 seconds, the year starts ashing, You can press MEM button to increase contiously
1 by 1 until 2049 and then return to the original year. After year set is done, press SET button to go to Month/Date
setting.
Note : When the set value blinks continuously for 7 seconds without any other operation, the system automa-
tically switches o and conrms the previously set value.
Initial Month/Date is 1/01. When the month value is ashing, press MEM button and it will increase 1 by 1, press SET
button to go to date setting, and do in the same way to set the date.
After date set is done, press SET button to got to Hour/Minute setting.
Initial Hour/Minute is 01/01, When the hour display is ashing, press the MEM button, the hour will increase 1 by 1,
press SET button to go to minute setting, and do in the same way to set minute.
Pressure Unit Setting
The blood pressure value is displayed in mmHg/KPa and the default unit is mmHg. In the power o state, press and
hold the START/STOP button for 10 seconds to enter the unit setting interface. Press MEM button to select mmHg or
KPa. Press START/STOP button to save the selected unit automatically.
User ID(1 or 2) setting:
Short press the SET button, the user ID shows up, You can press SET button again to choose user ID 1 or user ID 2.
Note : When the set user ID shows continuously for 12 seconds without any other operation, the system automatical-
ly switches o and conrms the user setting. Or press START/STOP button after the user ID set immediately, system
automatically save the settings.
MEASUREMENT PROCEDURE
Before measurement:
• Avoid eating and smoking as well as all forms of exertion directly before measurement. These factors inuence the
measurement result. Find time to relax by sitting in an armchair in a quiet atmosphere for about ten minutes before
taking a measurement.
• Remove any garment that ts closely to your wrist.
• Always measure on the same arm (normally left).
Fitting the Cu
• Insert the connector of rubber tube into the cu jack. Make sure that they are properly connected.
• Wrap the cu around your left upper arm. The rubber tube should be on the inner side of your arm extending
downward to your hand. Make sure the lower edge of cu lies approximately 2 to 3 cm above the elbow. Important!
The ARTERY Mark on the lower edge of the cu must lie over your artery which runs down the inner side of your arm.

Właściciel serwisu: TERG S.A. Ul. Za Dworcem 1D, 77-400 Złotów; Spółka wpisana do Krajowego Rejestru Sądowego w Sądzie Rejonowym w Poznań-Nowe Miasto i Wilda w Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego pod nr KRS 0000427063, Kapitał zakładowy: 41 287 500,00 zł; NIP 767-10-04-218, REGON 570217011; numer rejestrowy BDO: 000135672. Sprzedaż dla firm (B2B): dlabiznesu@me.pl INFOLINIA: 756 756 756