Meaning of buttons and UPS components / Signication des boutons et des composants de l’ASI/ Signicado de
los botones y componentes del SAI/ Signicado dos botões e componentes da UPS/ Bedeutung der Tasten und USV-
Komponenten/ Betydelse av knappar och UPS-komponenter/ Signicato dei pulsanti e dei componenti dell’UPS/ Znaczenie
przycisków oraz elementów UPS-a/ Význam tlačítek a součástí UPS/ Význam tlačidiel a častí UPS/ Semnicația butoanelor și a
componentelor UPS/ Значение на бутоните и компонентите на UPS/ A gombok és az UPS-összetevők jelentése/ Значення
кнопок і компонентів ДБЖ/ Значение кнопок и компонентов ИБП/ Σημασία των κουμπιών και των εξαρτημάτων του UPS
TECHNICAL SPECIFICATION
1
2
4
3
5566
77
88
99
FRENCH OUTLETSCHUKO OUTLET
1
TABLE OF CONTENTS
EN - User Manual .....................................................................................................................................................................................2
FR - Manuel de l’utilisateur ..................................................................................................................................................................5
ES - Manual del usuario .........................................................................................................................................................................8
PT - Manual do Utilizador ...................................................................................................................................................................11
DE - Benutzerhandbuch ......................................................................................................................................................................14
SE - Användarhandbok ........................................................................................................................................................................17
IT - Manuale d’uso .................................................................................................................................................................................20
CZ - Návod k použití .............................................................................................................................................................................26
SK - Návod na použitie ........................................................................................................................................................................29
RO - Manual de utilizare ......................................................................................................................................................................32
BG - Ръководство за потребителя ................................................................................................................................................35
HU - Használati utasítás .......................................................................................................................................................................38
UA - Посібник користувача .............................................................................................................................................................41
RU - Руководство пользователя ....................................................................................................................................................44
GR - Εγχειρίδιο χρήσης ........................................................................................................................................................................47
32
EN - USER MANUAL
ATTENTION: Discharge and recharge the battery(s) every 3 months to ensure full battery life. Failure to follow this
process will shorten their life!
INTRODUCTION
• This product is designed to provide emergency power to devices such as cash registers, alarm systems, servers, consumer
electronics, computers.
• The product is not designed to work with household appliances that require a continuous pure sine wave such as hair
dryers, refrigerators, microwaves, washing machines, vacuum cleaners, fans, electric kettles, induction stoves and other
similar appliances. Do not connect items that can overload the UPS. The UPS system should not be used in life support
systems or other vital critical equipment.
SAFETY
• Risk of electric shock! Do not open the housing yourself, entrust servicing to a qualied person.
• Do not use the device in low or high temperatures, strong magnetic elds, or in humid or dusty environments.
• Do not obstruct the ventilation openings.
• Connect all wiring in a manner that complies with applicable local electrical codes and in such a way as to eliminate the
risk of stepping on or tripping over it. Use only VDE-certied and CE-certied power cables when connecting loads to the
UPS.
• In case of smoke coming out of the device, disconnect the mains supply as soon as possible. In case of re, disconnect the
mains supply as soon as possible and notify the re department of the situation by calling the re department number of
the country you are in.
SWITCHING ON THE UPS
Hold the power button for about 3 seconds to turn the unit on. The UPS will be ready for use from now on.
• The UPS has a „cold start” function that allows it to be turned on without being plugged into an AC outlet.
• Each time the UPS starts up, an automatic diagnostic test is carried out, which is indicated by alternating LED lights.
ATTENTION: Before starting the device for the rst time, check the casing of the device for visible damage caused in
transportation. If the casing has any damage or dents, do not start the device and contact your dealer.
SWITCHING OFF THE UPS
To turn o the device, hold down the power button for about 3 seconds.
• When shutting down in power supply (AC) mode, the UPS will stop supplying power to rear-connected devices and
will enter standby mode. Despite the shutdown, the UPS will continue to run in the background, charging the batteries.
Complete shutdown of the UPS occurs when the plug is removed from the AC outlet.
• When shutting down in battery (DC) mode, the UPS will shut down after a long beep.
CONNECTING THE UPS
Plug the UPS plug directly into a veried 3-wire grounded AC outlet. Do not connect the UPS to any surge suppressors,
splitters or power strips.
CONNECTING EXTERNAL DEVICES (LOADS)
Plug the UPS plug into the output power socket (7), located on the back of the UPS. Do not use adapters, splitters or outlet
replacements to swap the output type of the output socket.
• If the UPS is overloaded during its operation, it will shut down automatically after 10 seconds if no preventive steps are
taken by the user.
MANAGEMENT SOFTWARE
The product has software that allows you to monitor and manage UPS operating parameters from your computer. To do so,
download the software from www.armac.com.pl/en.
Meaning of buttons and UPS components
1. Mains (AC) power ON/OFF button
2. LED indicating that the device is operating in mains (AC) power mode
3. LED indicating that the device is operating in battery (DC) mode
4. LED indicating that the device is overloaded
5. USB port
6. RJ-11/RJ-45 port
7. Fuse
8. Input power cable
9. French (E) / Schuko (F) type power outlets
UPS sound signals and their meaning
The device beeps every 8 secondsUPS went into battery mode
The device beeps every 1 secondHold time is less than 1 minute
The device emits a continuous soundUPS is overloaded
MAINS POWER SUPPLY MODE (AC)
When the UPS is operating in the mains (AC) mode, the green LED indicator will continuously light up to indicate normal UPS
operation. While the load level reaches over 100%, the red LED indicator will icker and the unit will emit long beeps. Please
use the dedicated software to check the current input voltage and AC output voltage.
• When mains (AC) power is restored after a sudden loss of power, the UPS will automatically start up and return to normal
operation.
BATTERY MODE (DC)
While the UPS is operating in battery power (DC) mode, the orange LED indicator will be continuously lit and the UPS will
beep every 8 seconds. While the battery level is low, the orange LED indicator will be continuously lit and the unit will beep
every second. When the UPS is overloaded, the red LED indicator will icker and the unit will beep for a long time. When the
battery is almost depleted, the UPS will shut down automatically. To check the current input voltage and output voltage of
the mains supply, please use the dedicated software.
• To turn o the beeps in battery mode, briey press the switch.
CONTACT
When contacting service or technical support, prepare the following information:
• UPS model number and its serial number;
• Identify the date or time when the problem occurred;
• Full description of the problem that occurs in the device or during its operation
WARRANTY AND SERVICING
Unauthorized repair or disassembly will void the warranty and may damage the product. Breaking or damaging the warranty
seal and improper use will void the warranty.
Entrust servicing to qualied technical personnel.
Batteries should be replaced with batteries of the same type and with the same number of sealed electrolyte chambers.
Batteries should be disposed of in accordance with applicable standards and regulations in the country where they are used.
TROUBLESHOOTING
Before checking for possible problems with the device, check if:
• The UPS is properly connected to the output power outlet;
• The voltage present on the line is specied;
• The fuse or circuit protection device on the rear panel is open.
Troubleshooting table
54
SymptomPossible reasonPossible solution
UPS cannot be turned on
UPS is not connected to the mains and
is overloaded
Plug the UPS to the mains and remove
the load
Input fuse is turned o
Reset the fuse (press it again), remove
some of the load or check that the
load does not have a short circuit or is
damaged
The voltage input is too lowCheck if the power supply voltage is
too low
UPS malfunctionSend the device to the local service for
repair purposes.
UPS beeps every 8 secondsUPS switches to battery mode, despite
the current power
Promptly save data and turn o the
devices connected to the UPS
UPS beeps every secondRemaining backup time is shorter
than 1 minute
Turn o the operating system and
charge the UPS again
UPS emits a constant beepingUPS is overloaded. For protection
purposes, it has been switched o
Remove the load, which may cause
the inclusion of security
Backup time is shorter than the
specication
UPS is overloadedReduce the UPS load
The battery is not fully charged
Recharge the batteries again for at
least 12 hours and retest the backup
time
The charger is damagedSend the device to the local service for
repair purposes.
STORAGE